        新聞中心

        主機組又無制冷作用拉力試驗機

        發布時間:2020-06-03 來源:濟南力華測試系統有限公司 瀏覽:

        主機無制冷效果拉伸試驗機

        首先查看恒溫恒濕試驗箱是否在低溫下長時間運行。 當可編程恒溫恒濕試驗箱完成低溫運行后,蒸發器結冰,干燥溫度為60℃后約30分鐘。打開箱門解決恒溫恒濕的問題。 盒子不涼。

        Whether the electrical circuit of the constant temperature and humidity box is operating normally. Since the temperature of the constant temperature and humidity box cannot be maintained, observe whether the refrigeration compressor can be started during the operation of the test box, and the compressor can be started during the operation of the environmental test equipment. The electrical circuit is normal, and there is no problem in the electrical system.

        電氣系統沒有問題,然后檢查制冷系統。 首先檢查兩個制冷單元的低溫(R23)壓縮機的排氣壓力和吸入壓力是否低于正常值,并抽空吸入壓力,這表明主制冷單元的制冷劑量不足。

        是否缺少恒溫恒濕箱的制冷劑,用手觸摸主機R23壓縮機的排氣管路和吸氣管路,發現排氣管路的溫度不高,吸入管路的溫度不高。 不低(無霜),Farui Instruments告訴您主機組中缺少R23制冷劑。

        1.不確定恒溫恒濕室的故障原因,結合測試室的控制過程進一步確定故障的原因。 測試室有兩組制冷單元。

        2.一個是主單元,另一個是輔助單元。 當冷卻速率大時,兩組單元同時工作。 在溫度維護階段開始時,兩組單元仍同時工作。 溫度穩定后

        迄今為止,已經確認恒溫恒濕試驗室的生產失敗是由于主機組的低溫(R23)類單元的制冷劑R23的泄漏引起的。 通過將泄漏檢測器和肥皂水組合的方法來檢查制冷系統的泄漏檢測,發現熱氣旁通電磁閥的閥桿被約1cm的縫隙弄裂了。 更換電磁閥,為系統充氟,系統正常運行。 Farui儀器告訴您,從上面可以看出,對該故障現象的分析和判斷基本上很難,并且首先對電氣的靜脈進行分析和判斷,然后對冷卻進行分析,然后熟悉并理解 測試室原理和工作過程是分析故障和判斷故障的基礎。

        推薦產品PRODUCTS

        友情鏈接:
        三个老头把我啃个遍 <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <文本链> <文本链> <文本链> <文本链> <文本链> <文本链>